View Full Version : Huebsch stack dryer problem
Khach
06-20-2005, 04:34 PM
My Huebsch stack dryer HTT30BC upper pocket starts normally for about 4-5 minutes then stop. If I leave it for few minutes and press start, it will start for few minutes and stop again, and same thing happen again then again.
The lower pocket has no problem at all.
Can you help to tell which part do I have to check and replace?
Thanks,
Fred50
06-20-2005, 08:06 PM
Do you get a door open message?
MSKLAUNDRY.
06-20-2005, 10:35 PM
You either have a motor which is going into termal overload or a bad motor relay. Do both cylinder motor and fan motor stop together?
Khach
06-21-2005, 12:29 AM
no door open message, and both cylinder motor and fan motor stop together
seem like the temp reachs certain degree and it stops
MSKLAUNDRY.
06-21-2005, 08:14 AM
If the both motors are stopping it probably is the relay which is located in the control box at the rear of the dryer. Make sure you look in the upper box, duh. There is a possiblility that it is the computer but more likely the relay. Try changing it with the bottom to see or simply replace it if you have a spare.
Khach
06-23-2005, 03:57 PM
It was the relay problem.
I am glad that I found coinwash so I can learn to fix these dryers/washers
Thank you so much MSKLAUNDRY for your help