PDA

View Full Version : mlg32dg wont start code d2


doubletap
06-07-2005, 05:58 PM
mlg32dg wont start code d2
reset and it works for awhile. problem affecting bottom dryer only

MSKLAUNDRY.
06-07-2005, 09:15 PM
Classic Maytag dryer problem!!!

Replace the thermistor above the lint draw and below the basket. Also make sure the molex connector as well as the wires to the thermistor are tight. The same goes for the molex connectors pins at the rear of the control box.

The part # is 130117 and you can get them from any parts distributor that sells ADC parts.

This problem is what keeps me busy, making $$$$ LOL.

And please don't call Fowler for the part!!! Those @#$%$*&.

doubletap
06-07-2005, 11:41 PM
Thanks Mark.
I have the same problem with the single load stack MLG23PDH, CODE d2 whats up here?

thanks

al

MSKLAUNDRY.
06-08-2005, 07:10 AM
The error codes are pretty much the same across there dryer line.

doubletap
06-08-2005, 09:03 AM
where is the thermistor in the single load stack dryer ?

MSKLAUNDRY.
06-08-2005, 06:37 PM
Remove the front panel. It is located on blower housing.